CTDC® – Certified TIA-942 Design Consultant

CTDC® – Certified TIA-942 Design Consultant -
CTDC® – Certified TIA-942 Design Consultant
  • CTDC® – Certified TIA-942 Design Consultant

    1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
    Loading...

    3 Dages kursus

    Certified Data Centre Training

    Kommende datoer

    Course Details

    CTDC® – Certified TIA-942 Design Consultant

    In this three-day course, the participant will learn how to design an ANSI/TIA-942 compliant data centre. It will provide a clear understanding of the requirements of the ANSI/TIA-942 Standard and possible implementation variations. This course is well suited for all types of data centres, be it enterprise data centres or multi-tenant, third party data centres such as co-location, managed services and cloud service providers.

    After completion of the course the participant will be able to:

    • Learn to properly comprehend and apply the ANSI/TIA-942 Standard requirements and guidelines
    • Understand the proper intent of the ANSI/TIA-942 Standard to avoid both over- and/or under-investment
    • Align the selection of redundancy levels and infrastructure investments to the business requirements.
    • Understand the criteria and requirements for a high-availability data centre design and how to effectively establish the data centre from the perspective of the ANSI/TIA-942 Standard
    • Understand how the ANSI/TIA-942 Standard relates to various worldwide standards
    Introduction to Data Centre Facilities

    About the ANSI/TIA-942

    • Life of the ANSI/TIA-942 Standard Relation to other standards
    • Architectural
    • Electrical
    • Mechanical
    • Telecommunication Areas under scope
    • High level redundancy de nitions Redundancy options (N, N+1 etc.) Fault tolerant
    • Concurrent maintainability Compartmentalisation Examples of redundancy levels

     

    Data Centre Space Planning

    Data Centre Topologies

    Recommendations for Energy Effciency

     

    Architectural

    • Site selection Parking
    • Multi-tenant building
    • Building construction

    Vapor barrier

    Roofing

    Floor loading

    Raised flooring

    Suspended/drop ceiling

    Hanging load

    Seismic

     

    Building Security & Safety

    • Security
    • CCTV Staffing
    • Bullet/ballistic proofing Lighting
    • Safety

    Signage

    Building and Room Access

    • Security checkpoints
    • Entry lobby
    • Doors and windows
    • Exit corridors
    • Shipping and receiving areas

     

    Room/Area Design Requirements

    • Administrative offices
    • Security office
    • Operations centre
    • Restroom and break room
    • UPS/Battery rooms
    • Generator and fuel storage area
    • Computer room

    Electrical

    • Utility power Substation Feed requirements Self-generation

     

    • HT/HV switch gear
    • Generator and fuel supply
    • LT/LV switch gear ATS Alternatives to ATS

     

    • UPS and batteries
    • PDU
    • STS
    • Grounding
    • Surge protection
    • EPO
    • Central power monitoring
    • Load banks
    • Testing

     

    • Equipment maintenance

    Preventive maintenance

    Facility training programs

     

    Mechanical

    • Environmental design Temperature and humidity requirements Contamination Sources Clean air Pressurisation Radio sources Vibration Water ingress
    • Water cooled systems Heat rejection Chilled water system Condenser water Make up water
    • Air cooled systems
    • HVAC control systems
    • Plumbing

    Pipe routing

    • Fire suppression
    • Water leak detection

    Telecommunications

    • Network topology
    • Redundancy level design
    • Media and connectors
    • Cabling pathways
    • Detailed cabling design considerations
    • Administration and labeling
    • Cable testing Data centre fabrics

    Exam

    Exam: Certified TIA-942 Design Consultant

    The primary audience for this course are professionals involved with designing, building, maintaining and operating mission critical data centres and those who wish to attend the CTIA® (Certified TIA-942 Internal Auditor) course.

    Participants must possess a valid data centre training certificate such as CDCP® or any other approved equivalent. Please submit a copy of your certificate for verification upon registration for the CTDC® course.